NixOS configuration for HPC cluster https://docs.hpc.informatik.hs-fulda.de/
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 

1.1 KiB

Network Details

Management Network

Each host (all nodes, management and storage) is attached to a dedicated management network.

VLAN: 1032
IPv4: 10.32.46.0/24
IPv6: 2001:638:301:202e::/64
DHCP: Enabled

Switch ports: 25 - 48

Hosts

10.32.46.10 - manager
10.32.46.100 - node-00
10.32.46.1xx - node-xx
10.32.46.120 - node-20

10.32.46.254 - switch

Data Network

VLAN: 1033
IPv4: 10.32.47.0/24
IPv6: 2001:638:301:202f::/64

Switch ports: 1 - 24

Hosts

10.32.47.10 - manager
10.32.47.100 - node-00
10.32.47.1xx - node-xx
10.32.47.120 - node-20

Switch configuration

The main switch, all interfaces are connected to, is split in two VLANs for management and data.

Management IP: 10.32.46.254/24

Enable SSH configuration

SSH login is enabled but quite unusable in the default state. To enable all config commands use the following procedure:

After login with username and password, enter the command:

_cmdline-mode on

Accept with yes and enter the following (vendor specific) password:

512900